Laboratory Bioreactors

MAGNETIC
DRIVE

Novel magnetic coupling agitator – top mounted.

SIEMENS SIMATIC
S7-1500

Based control and 15” panel ensure high process supervision.

USER-FRIENDLY,
EFFICIENT

Advanced Operator Panel: Marking, Actions, Recipes, Functionality.

TWO VESSEL
OPTIONS

Jacketed glass vessel and glass vessel with metallic jacketed bottom.

CLEANABLE
STERILE LID

Lid without welded components ensures ideal cleaning and sterility.

Microbiology

EDF-5.5-DB-MO

Double bottom vessel

The DB model features a jacketed stainless-steel bottom equipped with heating and cooling capabilities. It also features a sterilizable sampling valve at the bottom for convenient sample collection.

The MO configuration is designed to maximize microbiological processes, such as cultivating bacteria, yeasts, and mycelial cultures.

DB – Metallic double bottom vessel with sterilizable sampling valve.

MO – Configuration for cultivating bacteria, yeasts, and mycelial cultures.

Vessel

Total volume (L)   6.2

Working volume (L)   2 – 4.5

Vessel type  Metallic double bottom with bottom sterilizable sampler

Diameter/ Height (mm)   150/350

Aeration

Control   Rotameter, TMFC (option)

Gas supply   Air, + O2

Flow range, L/min   0.5 – 10

Sparger   Ring sparger

Filters   D51 mm 0.2 μm PTFE

Exhaust gas condenser Cooling from water – line or chiller

Mixing

Drive  Top magnetically coupled aseptic mixer

Rotation speed range (rpm)  40 – 1200

Mixer   2 Rushton turbines

Control

Controller   Siemens Simatic S7 – 1500

Operator panel   Touch screen BeeTronics, 15TS7 15’’ LED

Temperature   Built-in thermostat (heater – 500 W, chamber, recirculation pump, cooling water valve). Temperature control range from + 5 °C via coolant to 60 °C. Measurement accuracy ± 0,1 °C; accuracy of temperature regulation within the prescribed range is ± 0,2 °C (with option up to 90°C)

pH   Hamilton or Mettler Toledo sensors (different options, including Arc).
Acid/ Base
2 – 12 +/- 0,01pH units

pO2   Hamilton or Mettler Toledo sensors (different options, including Arc).
Control: mixing + O2 + substrate feeding.
0 – 150 % +/- 1%

Foam / Level   Conductivity sensor

Feeding   0.2 – 40 ml/min according adjusted profile

Peristaltic pumps   4 built – in stepper precision peristaltic pumps. External pump (option)

Dimensions

Total (mm)   930 (W) х 800(H) х 600(D)

Autocalving

Required place (mm)   590 (H) x 270 (D)

Microbiology

EDF-5.5-JG-MO

Double bottom vessel

The JG model features a jacketed glass vessel. The double jacketed glass vessel enables faster heating, while the expanded heating surface ensures more even distribution of heat. Samples are collected from the top using a syringe.

The MO configuration is designed to maximize microbiological processes, such as cultivating bacteria, yeasts, and mycelial cultures.

JG – Classic jacketed glass vessel.

MO – Configuration for cultivating bacteria, yeasts, and mycelial cultures.

Vessel

Total volume (L)   6.2

Working volume (L)   2 – 5

Vessel type   Jacketed glass vessel

Diameter/ Height (mm)   150/350

Aeration

Control   Rotameter, TMFC (option)

Gas supply   Air, + O2

Flow range, L/min   0.5 – 10

Sparger   Ring sparger

Filters   D51 mm 0.2 μm PTFE

Exhaust gas condensor   Cooling from water – line or chiller

Mixing

Drive Top magnetically coupled aseptic mixer

Rotation speed range (rpm)  40 – 1200

Mixer   2 Rushton turbines

Control

Controller   Siemens Simatic S7 – 1500

Operator panel   Touch screen BeeTronics, 15TS7 15’’ LED

Temperature   Built-in thermostat (heater – 500 W, chamber, recirculation pump, cooling water valve). Temperature control range from + 5 °C via coolant to 60 °C. Measurement accuracy ± 0,1 °C; accuracy of temperature regulation within the prescribed range is ± 0,2 °C (with option up to 90°C)

pH   Hamilton or Mettler Toledo sensors (different options, including Arc).
Acid/ Base
2 – 12 +/- 0,01pH units

pO2   Hamilton or Mettler Toledo sensors (different options, including Arc).
Control: mixing + O2 + substrate feeding.
0 – 150 % +/- 1%

Foam / Level   Conductivity sensor

Feeding   0.2 – 40 ml/min according adjusted profile

Peristaltic pumps   4 built – in stepper precision peristaltic pumps. External pump (option)

Dimensions

Total (mm)   930 (W) х 800(H) х 600(D)

Autocalving

Required place (mm)   510 (H) x 270 (D)

Cell cultures

EDF-5.5-DB-CC

Double bottom vessel

The DB model features a jacketed stainless-steel bottom equipped with heating and cooling capabilities. It also features a sterilizable sampling valve at the bottom for convenient sample collection.

The CC configuration is perfect for cell cultivation, for example, mammalian and plant cells.

DB – Metallic double bottom vessel with sterilizable sampling valve.

CC – Configuration for cultivating mammalian and plant cells.

Vessel

Total volume (L)   6.2

Working volume (L)   2 – 5

Vessel type  Metallic double bottom with bottom sterilizable sampler

Diameter/ Height (mm)   150/350

Aeration

Control   Rotameter, TMFC (option)

Gas supply   Air/CO2, + O2, N2; Air/CO2 in headspace

Flow range, L/min   0.1 – 2 (other – option)

Sparger   Microsparger

Filters   D51 mm 0.2 μm PTFE

Exhaust gas condensor   Cooling from water – line or chiller

Mixing

Drive Top magnetically coupled aseptic mixer

Rotation speed range (rpm)  40 – 500

Mixer  2 pitched blade impellers

Control

Controller   Siemens Simatic S7 – 1500

Operator panel   Touch screen BeeTronics, 15TS7 15’’ LED

Temperature   Built-in thermostat (heater – 500 W, chamber, recirculation pump, cooling water valve). Temperature control range from + 5 °C via coolant to 60 °C. Measurement accuracy ± 0,1 °C; accuracy of temperature regulation within the prescribed range is ± 0,2 °C (with option up to 90°C)

pH   Hamilton or Mettler Toledo sensors (different options, including Arc). Acid/ Base Base/CO2 ; 2 – 12 +/- 0,01pH units

pO2   Hamilton or Mettler Toledo sensors (different options, including Arc). Control: mixing + air/ O2/ N2 / CO2 (option); 0 – 150 % +/- 1%

Foam / Level   Conductivity sensor

Feeding   0.2 – 40 ml/min according adjusted profile

Peristaltic pumps   4 built – in stepper precision peristaltic pumps. External pump (option)

Dimensions

Total (mm)   930 (W) х 800(H) х 600(D)

Autocalving

Required place (mm)   590 (H) x 270 (D)

Cell cultures

EDF-5.5-JG-CC

Jacketed Glass vessel

The JG model features a jacketed glass vessel with stainless-steel bottom. The double jacketed glass vessel enables faster heating, while the expanded heating surface ensures more even distribution of heat. Samples are collected from the top using a syringe.

The CC configuration is perfect for cell cultivation, for example, mammalian and plant cells.

JG – Classic jacketed glass vessel.

CC – Configuration for cultivating mammalian and plant cells.

Vessel

Total volume (L)   6.2

Working volume (L)   2 – 5

Vessel type  Jacketed glass vessel

Diameter/ Height (mm)   150/350

Aeration

Control   Rotameter, TMFC (option)

Gas supply   Air/CO2, + O2, N2;  Air/CO2 in headspace

Flow range, L/min   0.1 – 2 (other – option)

Sparger   Microsparger

Filters   D51 mm 0.2 μm PTFE

Exhaust gas condensor  Cooling from water – line or chiller

Mixing

Drive Top magnetically coupled aseptic mixer

Rotation speed range (rpm)  40 – 500

Mixer  2 pitched blade impellers

Control

Controller   Siemens Simatic S7 – 1500

Operator panel   Touch screen BeeTronics, 15TS7 15’’ LED

Temperature   Built-in thermostat (heater – 500 W, chamber, recirculation pump, cooling water valve). Temperature control range from + 5 °C via coolant to 60 °C. Measurement accuracy ± 0,1 °C; accuracy of temperature regulation within the prescribed range is ± 0,2 °C (with option up to 90°C)

pH   Hamilton or Mettler Toledo sensors (different options, including Arc). Acid/ Base Base/CO2 ; 2 – 12 +/- 0,01pH units

pO2   Hamilton or Mettler Toledo sensors (different options, including Arc). Control: mixing + air/ O2/ N2 / CO2; 0 – 150 % +/- 1%

Foam / Level   Conductivity sensor

Feeding   0.2 – 40 ml/min according adjusted profile

Peristaltic pumps   4 built – in stepper precision peristaltic pumps. External pump (option)

Dimensions

Total (mm)   930 (W) х 800(H) х 600(D)

Autocalving

Required place (mm)   590 (H) x 270 (D)

Microbiology

EDF-5.5-DB-PBR

Double bottom vessel

The DB model features a jacketed stainless-steel bottom equipped with heating and cooling capabilities. It also features a sterilizable sampling valve at the bottom for convenient sample collection.

The PBR configuration is perfect for cultivation of phototrophic microorganisms, for example, cyanobacteria and Green Algae.

The vessel features a programmable LED array that is easy to remove, allowing for a fast and clean setup.

DB – Metallic double bottom vessel with sterilizable sampling valve.

PBR – Configuration for cultivation of phototrophic microorganisms.

Vessel

Total volume (L)   6.2

Working volume (L)   2 – 5

LED Lighting   Removable LED Light. Intensity control range – 0 – 1500 μmol/m2/s. Screen surface – 1350 cm2.

Vessel type   Metallic double bottom with bottom sterilizable sampler

Diameter/ Height (mm)   150/350

Aeration

Control   Rotameter, TMFC (option)

Gas supply   Air, + O2

Flow range, L/min   0.5 – 10

Sparger   Ring sparger

Filters   D51 mm 0.2 μm PTFE

Exhaust gas condensor   Cooling from water – line or chiller

Mixing

Drive  Top magnetically coupled aseptic mixer

Rotation speed range (rpm)  40 – 1200

Mixer   2 Rushton turbines (Interchangeable pitched blade option)

Control

Controller   Siemens Simatic S7 – 1500

Operator panel   Touch screen BeeTronics, 15TS7 15’’ LED

Temperature   Built-in thermostat (heater – 500 W, chamber, recirculation pump, cooling water valve). Temperature control range from + 5 °C via coolant to 60 °C. Measurement accuracy ± 0,1 °C; accuracy of temperature regulation within the prescribed range is ± 0,2 °C (with option up to 90°C)

pH   Hamilton or Mettler Toledo sensors (different options, including Arc).
Acid/ Base; 2 – 12 +/- 0,01pH units

pO2   Hamilton or Mettler Toledo sensors (different options, including Arc).
Control: mixing + O2 + substrate feeding; 0 – 150 % +/- 1%

Foam / Level   Conductivity sensor

Feeding   0.2 – 40 ml/min according adjusted profile

Peristaltic pumps   4 built – in stepper precision peristaltic pumps. External pump (option)

Dimensions

Total (mm)   930 (W) х 800(H) х 600(D)

Autocalving

Required place (mm)   590 (H) x 270 (D)

Microbiology

EDF-5.5-DB-PBRMO

Metallic double bottom with bottom sterilizable sampler With LED panels

The DB model features a jacketed stainless-steel bottom equipped with heating and cooling capabilities. It also features a sterilizable sampling valve at the bottom for convenient sample collection.

The PBR-MO configuration is perfect for cultivation of phototrophic and microbiological microorganisms such as, cyanobacteria, yeasts.

The vessel features a programmable LED array that is easy to remove, allowing for a fast and clean setup.

DB – Metallic double bottom vessel with sterilizable sampling valve.

PBR-MO – Configuration for cultivating phototrophic microorganisms, bacteria, yeasts, and mycelial cultures.

Vessel

Total volume (L)   6.2

Working volume (L)   2 – 5

LED Lighting   None

Vessel type  Jacketed glass vessel

Diameter/ Height (mm)   150/350

Aeration

Control   Rotameter, TMFC (option)

Gas supply   Air, + O2

Flow range, L/min   0.5 – 10

Sparger   Ring sparger

Filters   D51 mm 0.2 μm PTFE

Exhaust gas condensor   Cooling from water – line or chiller

Mixing

Drive  Top magnetically coupled aseptic mixer

Rotation speed range (rpm)  40 – 1200

Mixer   2 Rushton turbines

Control

Controller   Siemens Simatic S7 – 1500

Operator panel   Touch screen BeeTronics, 15TS7 15’’ LED

Temperature   Built-in thermostat (heater – 500 W, chamber, recirculation pump, cooling water valve). Temperature control range from + 5 °C via coolant to 60 °C. Measurement accuracy ± 0,1 °C; accuracy of temperature regulation within the prescribed range is ± 0,2 °C (with option up to 90°C)

pH   Hamilton or Mettler Toledo sensors (different options, including Arc).
Acid/ Base; 2 – 12 +/- 0,01pH units

pO2   Hamilton or Mettler Toledo sensors (different options, including Arc).
Control: mixing + O2 + substrate feeding; 0 – 150 % +/- 1%

Foam / Level   Conductivity sensor

Feeding   0.2 – 40 ml/min according adjusted profile

Peristaltic pumps   4 built – in stepper precision peristaltic pumps. External pump (option)

Dimensions

Total (mm)   930 (W) х 800(H) х 600(D)

Autocalving

Required place (mm)   590 (H) x 270 (D)

Book a Consultation​

Get a Quote - EDF-5.5-DB-MO

Get a Quote - EDF-5.5-JG-MO

Get a Quote - EDF-5.5-DB-CC